Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 388
Filtrar
1.
Surg Endosc ; 37(7): 5438-5443, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37038022

RESUMO

PURPOSE: Mediumweight (MW) and heavyweight (HW) polypropylene have demonstrated similar clinical and patient-reported outcomes in the setting of open retromuscular ventral hernia repair (VHR). While MW mesh has an anecdotal risk of central mesh fracture, that phenomenon is not well-characterized. We sought to assess the incidence of and risk factors for MW polypropylene mesh fractures after VHR. METHODS: The ACHQC registry was queried for patients with CT-documented hernia recurrence after open retromuscular VHR with MW polypropylene mesh at our institution with 1-year follow-up between January 2014 and April 2022. Images were reviewed by five blinded surgeons at Cleveland Clinic to reach consensus that hernia recurrence mechanism was central mesh fracture. Patients without clinical recurrence or patient-reported bulge were used as a comparator group. RESULTS: Eighty patients were identified with radiographically documented recurrence; 28 had recurrence from mesh fractures and these were compared to 644 patients without recurrence. Incidence of MW fracture was 4.2%. Bridging of anterior fascia was more common in the group with the central mesh fracture (33.3% vs 3.3%, p < 0.001); the incidence of fracture was 30% (9/30) in patients requiring a bridged closure. Mesh fracture was associated with larger hernias (median width: 20 cm [16-26] vs 15 cm [12-18], p < 0.001,), length (25 cm [23-30] vs 23 cm [19-26], p = 0.004). CONCLUSION: MW polypropylene mechanical failures are surprisingly common, particularly in settings of bridged fascial closure and larger hernias. Use of HW polypropylene should be considered in this setting, and industry should be encouraged to create larger pieces of HW polypropylene mesh.


Assuntos
Hérnia Ventral , Polipropilenos , Humanos , Polipropilenos/efeitos adversos , Incidência , Telas Cirúrgicas/efeitos adversos , Hérnia Ventral/epidemiologia , Hérnia Ventral/etiologia , Hérnia Ventral/cirurgia , Fatores de Risco , Herniorrafia/efeitos adversos , Herniorrafia/métodos , Recidiva
2.
Adv Skin Wound Care ; 36(5): 1-4, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37079795

RESUMO

ABSTRACT: Cutaneous foreign bodies are a well-known cause of delayed wound healing and complications such as abscesses, fistula formation, and secondary infections. Polypropylene sutures are widely utilized in cutaneous surgery because they easily travel through tissues while eliciting minimal tissue reactions. Despite these advantages, retained polypropylene sutures can cause complications. The authors report a case of a retained polypropylene suture that remained buried after a total excision 3 years prior. It started to cause cutaneous symptoms when the patient began exercising 1 week prior to presentation. The authors also examine the dermatoscopic and dermatopathologic features and other complications related to retained polypropylene sutures that have been reported in the literature.


Assuntos
Fístula , Polipropilenos , Humanos , Pré-Escolar , Polipropilenos/efeitos adversos , Suturas/efeitos adversos , Pele , Procedimentos Cirúrgicos Dermatológicos
3.
J Gene Med ; 25(6): e3483, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36786034

RESUMO

BACKGROUND: Polypropylene is a thermoplastic polymer playing the role of an endocrine disruptor that interferes with the union, emission, transport or elimination of normal hormones. Epidemiological information indicated the relation of endocrine-disturbing chemicals with prostate cancer, testis tumor and diminished fertility. p53 is a key tumor silencer gene. The present study aimed to evaluate luteinizing hormone (LH) and follicle-stimulating hormone (FSH) levels and the risk of p53 mutations as a result of exposure to polypropylene in non-tumorous adult male factory workers. METHODS: In total, 150 (controls = 35, workers = 115) subjects were recruited. Groups were maintained according to the tenure of exposure G1 (1-5 years), G2 (6-10 years), G3 (11-15 years) and G4 (16-20 years). Concentrations of LH and FSH were determined through an enzyme-linked immunosorbent assay. Genotyping analysis was performed by polymerase chain reaction based gel electrophoresis followed by DNA sequencing. The structural and functional impact of the mutation on the p53 structure was evaluated using 50-ns molecular dynamics (MD) simulations and protein-DNA docking. RESULTS: Mean plasma LH levels were significantly decreased in G1 (p > 0.05) as well as the G2, G3 and G4 (p > 0.001) groups. Similarly, FSH levels were significant decrease in G1 (p > 0.05), G2 (p > 0.01), G3 (p > 0.001) and G4 (p > 0.001) compared to the control group. Sequencing results found three variants i.e. g.13450 T>G, g.13430C>T and g.13737G>A. One of them was predicted to be disease-causing others are polymorphisms. MD simulation of missense mutation R273H showed no structural impact on the protein structure in MD simulation, but it resulted in weaker binding of p53 with the DNA that might lower the gene expression of cell cycle regulatory proteins. CONCLUSIONS: These findings predict decreased fertility and risk of malignancies in the future. The spectrum of p53 mutations as a result of polypropylene exposure in the Pakistani population has not been investigated before. Further studies and meta-analyses are required to elucidate the role of different plasticizers in reproduction and cancer-causing risk factors in a larger population.


Assuntos
Hormônio Foliculoestimulante , Neoplasias , Adulto , Masculino , Humanos , Polipropilenos/efeitos adversos , Genes p53 , Proteína Supressora de Tumor p53/genética , Hormônio Luteinizante , Mutação
5.
J Biomed Mater Res A ; 111(8): 1110-1119, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36583666

RESUMO

Polypropylene degradation in vivo appears as mesh surface cracking and peeling. This aging process of the mesh, resulting in the lack of bio-stability, contradicts the requirement of biocompatibility. However, to date, it is still not clearly established how much this mesh degradation influences the local tissue response with subsequent clinical consequences. This study aims to find out whether mesh degradation is correlated with elevated inflammatory tissue reaction through analyzing 100 human PP meshes explanted from the pelvic floor. A degradation classification method, based on standard pathological H&E stained slides of the explanted mesh via light microscope, was developed to classify the mesh degradation into four classes (no, mild, moderate and severe degradation). The peri-filamentary tissue inflammatory reaction was analyzed by scoring the expression of the most common cell markers for the innate immune reaction: CD68 as marker for macrophage, CD86 for M1 subtype, CD163 for M2 subtype, CD3 for T-lymphocyte and CD15 for neutrophil granulocytes. The correlation between immune cell expression, degradation classification and time of implantation of the meshes are evaluated with Spearman-Rho-Test. Mesh degradation worsens significantly (p < .001) with longer time of implantation. The increasing tendency of CD68 expression by mesh with higher degradation class indicates that the number of macrophages increases with worsening mesh degradation. The significantly increased expression of CD163 and CD3 cell by severely degraded mesh demonstrate the increased number of M2 and T-Lymphocyte when mesh degradation becomes severe. None of the inflammatory cells show the usual declining expression with longer time of implantation. The result of this study suggests that the degradation of PP mesh results in an elevated local inflammatory reaction in female pelvic floor. A material with better bio-stability for mesh implant in pelvic floor is required.


Assuntos
Polipropilenos , Telas Cirúrgicas , Humanos , Feminino , Polipropilenos/efeitos adversos , Telas Cirúrgicas/efeitos adversos , Inflamação/metabolismo , Macrófagos/metabolismo , Próteses e Implantes
6.
Acta Biomater ; 148: 323-335, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35671876

RESUMO

Polypropylene meshes used in pelvic organ prolapse (POP) repair are hampered by complications. Most POP meshes are highly unstable after tensioning ex vivo, as evidenced by marked deformations (pore collapse and wrinkling) that result in altered structural properties and material burden. By intentionally introducing collapsed pores and wrinkles into a mesh that normally has open pores and remains relatively flat after implantation, we reproduce mesh complications in vivo. To do this, meshes were implanted onto the vagina of rhesus macaques in nondeformed (flat) vs deformed (pore collapse +/- wrinkles) configurations and placed on tension. Twelve weeks later, animals with deformed meshes had two complications, (1) mesh exposure through the vaginal epithelium, and (2) myofibroblast proliferation with fibrosis - a mechanism of pain. The overarching response to deformed mesh was vaginal thinning associated with accelerated apoptosis, reduced collagen content, increased proteolysis, deterioration of mechanical integrity, and loss of contractile function consistent with stress shielding - a precursor to mesh exposure. Regional differences were observed, however, with some areas demonstrating myofibroblast proliferation and matrix deposition. Variable mechanical cues imposed by deformed meshes likely induce these two disparate responses. Utilizing meshes associated with uniform stresses on the vagina by remaining flat with open pores after tensioning is critical to improving outcomes. STATEMENT OF SIGNIFICANCE: Pain and exposure are the two most reported complications associated with the use of polypropylene mesh in urogynecologic procedures. Most meshes have unstable geometries as evidenced by pore collapse and wrinkling after tensioning ex vivo, recapitulating what is observed in meshes excised from women with complications in vivo. We demonstrate that collapsed pores and wrinkling result in two distinct responses (1) mesh exposure associated with tissue degradation and atrophy and (2) myofibroblast proliferation and matrix deposition consistent with fibrosis, a tissue response associated with pain. In conclusion, mesh deformation leads to areas of tissue degradation and myofibroblast proliferation, the likely mechanisms of mesh exposure and pain, respectively. These data corroborate that mesh implantation in a flat configuration with open pores is a critical factor for reducing complications in mesh-augmented surgeries.


Assuntos
Prolapso de Órgão Pélvico , Polipropilenos , Animais , Feminino , Fibrose , Humanos , Macaca mulatta , Dor , Prolapso de Órgão Pélvico/metabolismo , Prolapso de Órgão Pélvico/cirurgia , Polipropilenos/efeitos adversos , Polipropilenos/química , Telas Cirúrgicas/efeitos adversos , Vagina/metabolismo , Vagina/cirurgia
8.
J Surg Res ; 275: 56-62, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35220145

RESUMO

BACKGROUND: Barrier-coated meshes were designed to reduce adhesion formation between mesh and the surrounding viscera. There have been questions raised but little data to determine if rapidly absorbable coatings pose an increased risk of infection. The objective of this study was to determine if a difference exists in wound and mesh infection rates between coated and uncoated polypropylene mesh in patients undergoing open ventral hernia repair. METHODS: A prospective, institutional database at a tertiary hernia center identified patients undergoing open preperitoneal ventral hernia repair (OPPVHR) with polypropylene mesh in CDC class 1 and 2 wounds. Using propensity score matching, an absorbable, coated and uncoated group were matched based on age, comorbidities, wound class, defect size, and mesh size. RESULTS: There were 265 patients each in the matched coated and uncoated mesh groups for a total of 530 patients. Postoperative wound infections (10.9% versus 4.6%, P = 0.01) and need for IV antibiotics (10.5% versus 4.3%, P = 0.01) were significantly higher in the coated group. There was an increase in mesh infection for the coated group (3.4% versus 0.4%, P = 0.02), and of those developing a mesh infection, 60.0% eventually required mesh excision. CONCLUSIONS: Coated mesh was associated with increased postoperative wound and mesh infection following OPPVHR. An uncoated mesh should be strongly considered when placed in an extraperitoneal location.


Assuntos
Parede Abdominal , Hérnia Ventral , Parede Abdominal/cirurgia , Hérnia Ventral/etiologia , Hérnia Ventral/cirurgia , Herniorrafia/efeitos adversos , Humanos , Polipropilenos/efeitos adversos , Estudos Prospectivos , Telas Cirúrgicas/efeitos adversos
9.
Hernia ; 26(2): 401-410, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35020091

RESUMO

PURPOSE: The surgical implantation of polypropylene (PP) meshes has been linked to the occurrence of systemic autoimmune disorders. We performed a systematic review to determine whether PP implants for inguinal, ventral hernia or pelvic floor surgery are associated with the development of systemic autoimmune syndromes. METHODS: We searched Embase, Medline, Web of Science, Scopus, Cochrane library, clinicaltrialsregister.eu, clinicaltrails.gov and WHO-ICTR platform. Last search was performed on November 24th 2021. All types of studies reporting systemic inflammatory/autoimmune response in patients having a PP implant for either pelvic floor surgery, ventral or inguinal hernia repair were included. Animal studies, case reports and articles without full text were excluded. We intended to perform a meta-analysis. The quality of evidence was assessed with the Newcastle-Ottawa Scale. This study was registered at Prospero (CRD42020220705). RESULTS: Of 2137 records identified, 4 were eligible. Two retrospective matched cohort studies focused on mesh surgery for vaginal prolapse or inguinal hernia compared to hysterectomy and colonoscopy, respectively. One cohort study compared the incidence of systemic conditions in women having urinary incontinence surgery with and without mesh. These reports had a low risk of bias. A meta-analysis showed no association when comparing systemic disease between mesh and control groups. Calculated risk ratio was 0.9 (95% CI 0.82-0.98). The fourth study was a case series with a high risk of bias, with a sample of 714 patients with systemic disease, 40 of whom had PP mesh implanted. CONCLUSION: There is no evidence to suggest a causal relationship between being implanted with a PP mesh and the occurrence of autoimmune disorders.


Assuntos
Doenças Autoimunes , Hérnia Inguinal , Animais , Doenças Autoimunes/complicações , Estudos de Coortes , Feminino , Hérnia Inguinal/etiologia , Hérnia Inguinal/cirurgia , Herniorrafia/efeitos adversos , Humanos , Polipropilenos/efeitos adversos , Estudos Retrospectivos , Telas Cirúrgicas/efeitos adversos , Síndrome
10.
Hernia ; 26(1): 309-323, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33788008

RESUMO

BACKGROUND: Polypropylene (PP) mesh is widely used to reinforce tissues. The foreign body reaction (FBR) to the implant is dominated by innate immune cells, especially macrophages. However, considerable numbers of adaptive immune cells, namely T cells, have also been regularly observed, which appear to play a crucial role in the long-term host response. METHODS: This study investigated the FBR to seven human PP meshes, which were removed from the abdomen for recurrence after a median of one year. Using immunofluorescence microscopy, the FBR was examined for various innate (CD11b+ myeloid, CD68+ macrophages, CD56+ NK) and adaptive immune cells (CD3+ T, CD4+ T-helper, CD8+ cytotoxic, FoxP3+ T-regulatory, CD20+ B) as well as "conventional" immune cells (defined as cells expressing their specific immune cell marker without co-expressing CD68). RESULTS: T-helper cells (19%) and regulatory T-cells (25%) were present at comparable rates to macrophages, and clustered significantly toward the mesh fibers. For all cell types the lowest proportions of "conventional" cells (< 60%) were observed at the mesh-tissue interface, but increased considerably at about 50-100 µm, indicating reduced stimulation with rising distance to the mesh fibers. CONCLUSION: Both innate and adaptive immune cells participate in the chronic FBR to PP meshes with T cells and macrophages being the predominant cell types, respectively. In concordance with the previous data, many cells presented a "hybrid" pattern near the mesh fibers. The complexity of the immune reaction seen within the foreign body granuloma may explain why approaches focusing on specific cell types have not been very successful in reducing the chronic FBR.


Assuntos
Polipropilenos , Telas Cirúrgicas , Abdome , Reação a Corpo Estranho/etiologia , Herniorrafia , Humanos , Polipropilenos/efeitos adversos , Telas Cirúrgicas/efeitos adversos
11.
Acta Cir Bras ; 36(7): e360706, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34495141

RESUMO

PURPOSE: To compare tissue inflammatory response, foreign body reaction, fibroplasia, and proportion of type I/III collagen between closure of abdominal wall aponeurosis using polyglactin suture and intraperitoneal implant of polypropylene, polypropylene/polyglecaprone, and polyester/porcine collagen meshes to repair defects in the abdominal wall of rats. METHODS: Forty Wistar rats were placed in four groups, ten animals each, for the intraperitoneal implant of polypropylene, polypropylene/polyglecaprone, and polyester/porcine collagen meshes or suture with polyglactin (sham) after creation of defect in the abdominal wall. Twenty-one days later, histological analysis was performed after staining with hematoxylin-eosin and picrosirius red. RESULTS: The groups with meshes had a higher inflammation score (p < 0.05) and higher number of gigantocytes (p < 0.05) than the sham group, which had a better fibroplasia with a higher proportion of type I/III collagen than the tissue separating meshes (p < 0.05). There were no statistically significant differences between the three groups with meshes. CONCLUSIONS: The intraperitoneal implant of polypropylene/polyglecaprone and polyester/porcine collagen meshes determined a more intense tissue inflammatory response with exuberant foreign body reaction, immature fibroplasia and low tissue proportion of type I/III collagen compared to suture with polyglactin of abdominal aponeurosis. However, there were no significant differences in relation to the polypropylene mesh group.


Assuntos
Parede Abdominal , Polipropilenos , Parede Abdominal/cirurgia , Animais , Aponeurose , Colágeno , Reação a Corpo Estranho/etiologia , Teste de Materiais , Poliglactina 910/efeitos adversos , Polipropilenos/efeitos adversos , Ratos , Ratos Wistar , Telas Cirúrgicas/efeitos adversos , Suturas , Suínos
12.
Nat Rev Urol ; 18(12): 725-738, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34545239

RESUMO

Polypropylene (PPL) mesh is widely used in pelvic floor reconstructive surgery for prolapse and stress urinary incontinence. However, some women, particularly those treated using transvaginal PPL mesh placement for prolapse, experience intractable pain and mesh exposure or extrusion. Explanted tissue from patients with complications following transvaginal implantation of mesh is typified by a dense fibrous capsule with an immune cell-rich infiltrate, suggesting that the host immune response has a role in transvaginal PPL mesh complications through the separate contributions of the host (patient), the biological niche within which the material is implanted and biomaterial properties of the mesh. This immune response might be strongly influenced by both the baseline inflammatory status of the patient, surgical technique and experience, and the unique hormonal, immune and microbial tissue niche of the vagina. Mesh porosity, surface area and stiffness also might have an effect on the immune and tissue response to transvaginal mesh placement. Thus, a regulatory pathway is needed for mesh development that recognizes the roles of host and biological factors in driving the immune response to mesh, as well as mandatory mesh registries and the longitudinal surveillance of patients.


Assuntos
Materiais Biocompatíveis/efeitos adversos , Reação a Corpo Estranho/etiologia , Prolapso de Órgão Pélvico/cirurgia , Polipropilenos/efeitos adversos , Complicações Pós-Operatórias/etiologia , Telas Cirúrgicas/efeitos adversos , Incontinência Urinária por Estresse/cirurgia , Feminino , Reação a Corpo Estranho/imunologia , Reação a Corpo Estranho/prevenção & controle , Procedimentos Cirúrgicos em Ginecologia/efeitos adversos , Procedimentos Cirúrgicos em Ginecologia/instrumentação , Humanos , Complicações Pós-Operatórias/imunologia , Complicações Pós-Operatórias/prevenção & controle , Fatores de Risco , Procedimentos Cirúrgicos Urológicos/efeitos adversos , Procedimentos Cirúrgicos Urológicos/instrumentação
13.
Dig Surg ; 38(4): 290-299, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34350869

RESUMO

INTRODUCTION: Laparoscopic paraesophageal hernia repair is an effective treatment for symptomatic paraesophageal hernias. To reduce recurrence rates, the use of prosthetics for the crural repair has been suggested. Mesh-related complications are rare but known to be disastrous. To address another form of crural repair, polypropylene strips are suggested. This study aimed to assess peri- and postoperative complications of reinforcement of cruroplasty with polypropylene strips. METHODS: From 2013 to 2020, patients with a primary or recurrent type 2, 3, or 4 paraesophageal hernia that underwent cruroplasty with polypropylene strips were retrospectively reviewed. Intra- and postoperative complications were graded according to the Clavien-Dindo classification. The incidence of symptomatic recurrent hiatal hernia (CT or endoscopy proven) and hospital stay were assessed. RESULTS: One hundred fifty-eight patients were included. Mean age was 65 years (standard deviation 10.4), and 119 patients were female (75.3%). Almost 50% of surgeries took place between 2018 and 2020. Median follow-up was 7 months (interquartile range 17.5). Mean operation time in the primary hernia group was 159 min (standard deviation 39.0), and length of stay was 4.4 days. In 3/158 patients (2.0%), intraoperative complications occurred. Two patients developed a grade 4 and seven patients a grade 3 postoperative complication. No mortality was recorded. Twelve recurrences (8.2%) were detected in the primary hernia group and one (9.1%) in the recurrent hernia group. CONCLUSION: There were no mesh-related complications seen and symptomatic recurrence rate was low, but longer follow-up is needed.


Assuntos
Hérnia Hiatal , Laparoscopia , Polipropilenos , Idoso , Feminino , Hérnia Hiatal/cirurgia , Humanos , Laparoscopia/métodos , Masculino , Pessoa de Meia-Idade , Polipropilenos/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos
14.
Bull Exp Biol Med ; 171(2): 265-269, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34173111

RESUMO

Morphometric and immunohistochemical examination of the vaginal mucosa before and 12 months after installation of polypropylene implants for the correction of stress urinary incontinence was performed in 20 patients with genital prolapse. The research results confirmed good biocompatibility of polypropylene and the formation of full-fledged connective tissue in the vaginal mucosa, but revealed the presence of a weak lymphocytic reaction to polypropylene 12 months after surgery. According to immunohistochemical study, increased contents of B lymphocytes and plasma cells responsible for the inductive and productive stages of the immune response were revealed in the vaginal mucosa around the implants 12 months after surgery. This reaction in the presences of provoking factors can lead to the development of inflammation and erosion, a type of mesh-associated complications.


Assuntos
Polipropilenos/efeitos adversos , Telas Cirúrgicas/efeitos adversos , Vagina/efeitos dos fármacos , Idoso , Feminino , Fibroblastos/efeitos dos fármacos , Fibroblastos/metabolismo , Fibroblastos/patologia , Humanos , Imuno-Histoquímica , Leucócitos/efeitos dos fármacos , Leucócitos/metabolismo , Leucócitos/patologia , Macrófagos/efeitos dos fármacos , Macrófagos/metabolismo , Macrófagos/patologia , Pessoa de Meia-Idade , Mucosa/efeitos dos fármacos , Mucosa/metabolismo , Mucosa/patologia , Prolapso de Órgão Pélvico/complicações , Prolapso de Órgão Pélvico/metabolismo , Prolapso de Órgão Pélvico/patologia , Prolapso de Órgão Pélvico/cirurgia , Polipropilenos/química , Complicações Pós-Operatórias/metabolismo , Complicações Pós-Operatórias/patologia , Próteses e Implantes/efeitos adversos , Incontinência Urinária por Estresse/complicações , Incontinência Urinária por Estresse/metabolismo , Incontinência Urinária por Estresse/patologia , Incontinência Urinária por Estresse/cirurgia , Vagina/metabolismo , Vagina/patologia
16.
J Minim Invasive Gynecol ; 28(8): 1503-1507, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33310165

RESUMO

STUDY OBJECTIVE: To evaluate suture complication rates and surgical outcomes according to the nonabsorbable suture materials used in vaginal uterosacral ligament suspension (USLS) surgery. Multifilament polyester (polyethylene terephthalate [PET]) and monofilament polypropylene (PP) sutures were compared. DESIGN: Retrospective cohort study. SETTING: Single teaching hospital. PATIENTS: Total of 229 patients who underwent transvaginal USLS and completed a 1-year follow-up. INTERVENTIONS: Use of PET and PP sutures for transvaginal USLS procedures. MEASUREMENTS AND MAIN RESULTS: PP sutures were used in 149 patients, and PET sutures were used in 80 patients. The suture-related complication rates, including granulation tissue and suture erosion at the vaginal apex, were significantly higher in the PET suture group than in the PP suture group (46.3% vs 20.1%, p <.01). However, there was no significant difference in the rates of surgical failure (defined as the presence of vaginal bulging symptoms, apical descent ≥ half of the total vaginal length, anterior or posterior vaginal wall descent beyond the hymen, or retreatment for prolapse) between the 2 groups (p = .84). CONCLUSION: Compared with the use of multifilament PET sutures, the use of monofilament PP sutures in transvaginal USLS may reduce suture-related complications without increasing surgical failure rates.


Assuntos
Prolapso de Órgão Pélvico , Prolapso Uterino , Feminino , Procedimentos Cirúrgicos em Ginecologia/efeitos adversos , Humanos , Ligamentos/cirurgia , Prolapso de Órgão Pélvico/cirurgia , Poliésteres/efeitos adversos , Polipropilenos/efeitos adversos , Estudos Retrospectivos , Suturas/efeitos adversos , Resultado do Tratamento
17.
Acta cir. bras ; 36(7): e360706, 2021. tab, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1339001

RESUMO

ABSTRACT Purpose To compare tissue inflammatory response, foreign body reaction, fibroplasia, and proportion of type I/III collagen between closure of abdominal wall aponeurosis using polyglactin suture and intraperitoneal implant of polypropylene, polypropylene/polyglecaprone, and polyester/porcine collagen meshes to repair defects in the abdominal wall of rats. Methods Forty Wistar rats were placed in four groups, ten animals each, for the intraperitoneal implant of polypropylene, polypropylene/polyglecaprone, and polyester/porcine collagen meshes or suture with polyglactin (sham) after creation of defect in the abdominal wall. Twenty-one days later, histological analysis was performed after staining with hematoxylin-eosin and picrosirius red. Results The groups with meshes had a higher inflammation score (p < 0.05) and higher number of gigantocytes (p < 0.05) than the sham group, which had a better fibroplasia with a higher proportion of type I/III collagen than the tissue separating meshes (p < 0.05). There were no statistically significant differences between the three groups with meshes. Conclusions The intraperitoneal implant of polypropylene/polyglecaprone and polyester/porcine collagen meshes determined a more intense tissue inflammatory response with exuberant foreign body reaction, immature fibroplasia and low tissue proportion of type I/III collagen compared to suture with polyglactin of abdominal aponeurosis. However, there were no significant differences in relation to the polypropylene mesh group.


Assuntos
Animais , Ratos , Polipropilenos/efeitos adversos , Parede Abdominal/cirurgia , Poliglactina 910/efeitos adversos , Telas Cirúrgicas/efeitos adversos , Suturas , Suínos , Teste de Materiais , Reação a Corpo Estranho/etiologia , Colágeno , Ratos Wistar , Aponeurose
18.
Int J Pharm ; 585: 119512, 2020 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-32526332

RESUMO

Pelvic Organ Prolapse (POP) and Stress Urinary Incontinence (SUI) are two prevalent disorders affecting 30-40% of women worldwide. Current strategies to repair or improve these medical conditions are non-surgical options such as physiotherapy, or surgical options such as the use of vaginal meshes. The synthetic material polypropylene (PP), which has long been used for manufacturing these vaginal meshes, is associated with severe complications such as chronic pain, infection or mesh erosion. As a result of a widespread reporting and unacceptably high rates of complications, these issues have become a public health concern. Regulatory bodies have recently deemed the transvaginal placement of PP mesh in the pelvic floor (PF) no longer a suitable treatment method for PF repair, leading to the need for a novel approach to the manufacture and selection of materials for urogynecological meshes. Medical devices, such as vaginal meshes can be manufactured using a variety of techniques including injection moulding, electrospinning, hot-melt extrusion (HME) or more recently 3D printing. Over the past decade, the use of 3D printing within the medical device industry has expanded and offers a promising approach to manufacture patient-specific surgical mesh when combined with imaging tools. This review will summarise the current strategies to treat POP and SUI, the issues and use of current meshes for the treatment of these pelvic floor disorders (PFDs), and the future directions for the manufacture of more suitable urogynecological meshes, as well as their potential materials.


Assuntos
Prolapso de Órgão Pélvico/cirurgia , Polímeros/química , Telas Cirúrgicas , Tecnologia Farmacêutica/métodos , Vagina , Corticosteroides/administração & dosagem , Antibacterianos/administração & dosagem , Materiais Biocompatíveis/química , Desenho de Equipamento , Falha de Equipamento , Feminino , Humanos , Ciência dos Materiais , Prolapso de Órgão Pélvico/complicações , Polipropilenos/efeitos adversos , Impressão Tridimensional , Incontinência Urinária por Estresse/etiologia
19.
Biomed Res Int ; 2020: 6761581, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32462011

RESUMO

AIMS: It is currently unknown whether an association exists between polypropylene mesh and urethral diverticulum formation following placement of polypropylene midurethral slings (MUS) for the treatment of stress urinary incontinence (SUI). We aimed to examine the literature associating MUS with the occurrence of urethral diverticula. METHODS: Multiple online research databases, including PubMed, Google Scholar, EBSCOhost, and the Cochrane Library, were searched, from January 2019 to February 2019, for evidence related to the occurrence of urethral diverticula following polypropylene MUS procedures. RESULTS: Four case reports were published demonstrating the occurrence of urethral diverticula following the use of polypropylene mesh for surgical treatment of SUI. Subjects of these cases were menopausal and had an elevated body mass index (BMI), recurrent urinary tract infections (UTIs), autoimmune conditions, or prior pelvic floor surgeries. A thorough urologic workup, including imaging prior to sling placement, was not always performed. CONCLUSION: No clear association exists between polypropylene MUS placement and subsequent urethral diverticulum formation. Factors that diminish polypropylene mesh biocompatibility include elevated BMI, menopause, recurrent UTIs, prior pelvic surgeries, and preexisting medical conditions. Symptoms associated with urethral diverticula should prompt a complete urologic workup prior to MUS placement.


Assuntos
Divertículo , Polipropilenos/efeitos adversos , Slings Suburetrais/efeitos adversos , Telas Cirúrgicas/efeitos adversos , Doenças Uretrais , Adulto , Divertículo/diagnóstico , Divertículo/etiologia , Divertículo/fisiopatologia , Humanos , Pessoa de Meia-Idade , Doenças Uretrais/diagnóstico , Doenças Uretrais/etiologia , Doenças Uretrais/fisiopatologia , Incontinência Urinária por Estresse/cirurgia
20.
Khirurgiia (Mosk) ; (3): 29-34, 2020.
Artigo em Russo | MEDLINE | ID: mdl-32271734

RESUMO

OBJECTIVE: Experimental assessment of the effect of modified and unmodified surgical suture material on abdominal adhesive process. MATERIAL AND METHODS: The study was performed on male rats of the Wistar subpopulation. There were 5 animals in each group. In all animals, midline abdominal incision was followed by suturing the parietal peritoneum with modified and unmodified suture material. All animals were euthanized with carbon dioxide vapors in 14 days after surgery. Macro- and microscopic assessment of severity of abdominal adhesive process was carried out. Two types of preparation of excised complexes 'peritoneum-suture material-adhesion' were applied for histological examination: paraffin sections and embedding in epoxy resin. Specimens were stained by Van Gieson and with methylene blue solution. Histological specimens were examined using Axio Imager A1 light microscope (Zeiss, Germany). RESULTS: Polypropylene filaments result extensive adhesions occupying about 75% of the area. Adhesions have a dense structure with signs of vascularization. Modification of suture material with solution of polyhydroxybutyrate/hydroxyvalerate and heparin reduce severity of adhesions. The use of modified suture material was followed by adhesions with more loose structure, no signs of vascularization. Adhesions occupied less than 25% of the area. Histological examination of excised complexes 'peritoneum-suture material-adhesion' revealed accumulation of inflammatory cells around the unmodified suture material, while there were no signs of tissue inflammatory process around the modified sutures. CONCLUSION: Application of polyhydroxybutyrate/hydroxyvalerate and heparin on the surface of surgical sutures is an effective method for prevention of abdominal adhesions.


Assuntos
Materiais Biocompatíveis/efeitos adversos , Heparina/administração & dosagem , Poliésteres/administração & dosagem , Polipropilenos/efeitos adversos , Suturas/efeitos adversos , Aderências Teciduais/prevenção & controle , Animais , Materiais Biocompatíveis/administração & dosagem , Materiais Revestidos Biocompatíveis/administração & dosagem , Materiais Revestidos Biocompatíveis/efeitos adversos , Modelos Animais de Doenças , Heparina/efeitos adversos , Masculino , Neovascularização Patológica/etiologia , Neovascularização Patológica/prevenção & controle , Peritônio/irrigação sanguínea , Peritônio/patologia , Peritônio/cirurgia , Poliésteres/efeitos adversos , Polipropilenos/administração & dosagem , Ratos , Ratos Wistar , Aderências Teciduais/etiologia , Aderências Teciduais/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...